Top human machine interface provider

Premium hmi touch screen panel manufacturer and supplier: Create the external model of the system function design model is mainly to consider the data structure, overall structure and process description of the software, interface design is generally only as an accessory, only the user’s situation (including age, gender, psychological situation, literacy, personality, ethnic background, etc.) have an understanding of the user to design an effective user interface; according to the end user’s hypothesis of the future system (referred to as the system hypothesis) The user model is designed to match the system image (external characteristics of the system) obtained after the system is implemented, so that the user can be satisfied with the system and can use it effectively; the information given by the system hypothesis should be fully considered when building the user model, and the system image must accurately reflect the syntactic and semantic information of the system. In short, only by understanding the user and the task can a good human-machine interface be designed. Find extra info at hmi touch screen panel.

Selecting the installation method: The installation mode of plc system is divided into centralized, remote i/o and distributed with multiple plc networking. Centralized hardware does not need to be set to drive remote i/o hardware, the system response is fast and cost is low; Remote I/O type is suitable for large systems, the system device distruibution range is very wide, remote i/o can be scattered installed near the field device, the connection is short, but need to add drivers and remote i/o power supply; The distrbuted network of multiple plc is suitable for the occasions where multiple devices are independently controlled and interconnected, and small plc can be selected, but communication module must be attaced.

Frequency principle: That is, according to the frequency of dialogue interaction of the management object design the human-machine interface hierarchical order and dialogue window display position of the list, etc., to improve the frequency of monitoring and access to dialogue. Importance principle: That is, in accordance with the importance of management objects in the control system and the global level, the design of the human-machine interface of the main and secondary menus and the location and prominence of the dialogue window, which helps managers to grasp the importance of the control system, the implementation of good control of the sequence of decisions to achieve optimal scheduling and management.

Choosing the right industrial hmi touch screen panel and plc can not only adapt to the electrical room’s multi-interference operation environment, but also enable each cabinet to achieve intelligent operation management, intelligent maintenance safety, intelligent new energy generation, etc., in order to achieve the goal of enhancing the electrical room’s core competitive advantage and promoting the sustainable development of electricity. Find extra info at https://www.mochuan-drives.com/.

Human-machine interface refers to the field of human and machine in information exchange and functional contact or mutual influence or interface said human-machine bonding surface, information exchange, functional contact or mutual influence, refers to the hard contact and soft touch of human and machine, this bonding surface includes not only the direct contact of the point line surface, but also the role of space for information transfer and control at a distance.

Less performance used to match a very high cost, so will it worth? And where is your market point? Maybe more consider another China brand with a very perfect performance too, such as Mochuan brand. Welcome contact us to discuss more. The Second Step: Selecting The HMI Screen Size There are two means of size here. One is screen display screen size, the other is CPU size. Integrating the scale of the entire project, to determine the size of the HMI panel needs, through the project as a whole to present the effect. Do not select the size is too small or too large, becuase too small is look very compact and not enough to operate in well, too large will look the overall proportion of the untuned and waste. It requires engineers to design a good enginnering diagram in advance to allocate the size of each accessory part of the proportion. Wanna win every high value market, it needs to pre-design and seriously selected, but not take for granted.

Use a multimeter to determine the test wiring according to the pins in the wiring diagram. Verify that the RS485 and RS232C wiring is correct, touch screens differ from various PLC wiring. This can be viewed by referring to Maintenance Control (help documentation for PLC and touch screen communication line connections), which is the basic method for normal troubleshooting of communication problems. Next I show you how to bypass the touch screen problem – online simulation. When communication fails, some customers will guess that there may be a problem with the touch panel interface or a problem with the interface. Online simulation means bypassing the touch screen and using the PLC to connect directly to the computer. Using our configuration software, the communication cable from the PLC itself is connected to the computer and an online simulation is carried out to see if the project can communicate. This can be done with a numerical input element or switch to see if the operation before and after closing the simulator and opening the online simulation is still present and if it prompts a direct NC (NC and previous operations not written down are not connected).

Mochuan hmi suppliers offer free software, NO MOQ, fast shipment, to deal with us your payment and business are in safe. Offering one-to-one technical support online. The most important, our hmi wholesale is compatible with all brands of plc controllers, such as, Mitsubish FX2N, FX3U, FX3SA, FX5U…Siemens S7-200, S7-300, S7-400,…etc, ABB, Acrel, Allen-Bradley(AB), Delta, Fatek, Fuji, LS, Omron, Panasonic etc. To learn, please have a look our software, there is one list to show it.

There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.

There is no a good way that a conventional resistive screen can be implemented, becuase its only support the operation temperature from 0°C to 50°C, it is far enough to meet. But Mochuan have another series type HMI panel, wide-temperature metal shell resistive hmi panel, supporting the operation temperature from -20°C to +70°C, it is very helpful to require higher or lower operation temperature working environment, such as Canada, Russia and America …etc, when winter is coming the temperature is very low. So this type metal shell hmi panel is the best choice. So it requires a good positioning, what type of HMI screen to select. For example, used in the renovation of equipment, used in the new development of equipment, the target market is high-end or low-end, whether the customer has special requirements, or to achieve a certain expected results, these factors should be taken into account, and then to make a correct choice is very necessary.