Turn-key project for clean room factory from SZ-pharma

Quality clean room sandwich panel company supplier: Tablet press is mainly used for tablet technology research in pharmaceutical industry. The tablet pressing machine presses powder or granular raw materials into tablets. Its scope of application: Traditional Chinese medicine, western medicine, health products, food, chemical industry, electronics and other industries. The prefabricated container house is a new concept of environmentally friendly and economical house with light steel H-shaped steel and channel steel as the framework, sandwich panel as the wallboard material, space combination with standard modulus series, and bolted or welded components. Find even more information on sandwich panel room.

Tablet punches and dies manufacturer in China: Obstacles such as work desks in the clean room will have eddy currents at the junctions, and the cleanliness will be relatively poor near them. Drilling air return holes on the work desks will minimize eddy currents; assembly Whether the selection of materials is appropriate and whether the equipment layout is perfect are also important factors for whether the airflow becomes a vortex phenomenon. The above introduction is related to clean room and airflow influencing factors.

Clean shed, also known as clean work shed (dust-free shed, purification shed, operating table, etc.), is a small space surrounded by anti-static mesh curtains or plexiglass in the clean room, and HEPA and FFU air supply units are used above. It is composed of a space with a higher purification level than the clean room, and the clean room can be equipped with purification equipment such as air shower room and transfer window.

Suzhou Pharma is one of the leading turnkey project providers for pharmaceutical, food, herbal, cosmetic, electronics factory and chemical plants. We offer projects as per GMP regulations. As being pioneers in this field, the solutions from Suzhou Pharma is readily accepted by the customers. Our solid expertise in cleanroom allows meeting the precise needs of its customer’s industry in different sectors such as health,pharmaceutical, biotechnology, and cosmetics. We firmly believe in the principle of quality by design. Discover more information on https://www.sz-pharma.com/.

Establish the use of standard operating specifications (SOP) and strict management: Items entering the clean room (aseptic room) basic requirements: All items entering the clean room (aseptic room) must be sterilized with disinfectant on the external surface in the first buffer room, and then sent to the aseptic room through the logistics buffer room, transfer window for more than 1 hour, and sterile air drying. Sterile indoor fixed items shall not be arbitrarily brought out. Personnel entering the clean room (aseptic room) requirements: experimental personnel entering the clean room (aseptic room) shall not make up, wear watches, rings and other jewelry. After cleaning your hands, you should enter the first buffer room and change your clothes. At the same time, you should change your disinfecting slippers, take off your coat, disinfect your hands with disinfectant, put on sterile gloves, change your sterile hoodie (do not expose your hair, clothes, etc.), and put on a sterile mask. Then put on a second pair of sterile gloves, and change a second pair of disinfectant isolation slippers when entering the second buffer room. Then through the air shower room 30s air shower into the sterile room.

Labeller is a device that pastes rolled self-adhesive paper labels (paper or metal foil) onto PCB, products or specified packaging. It has a wide range of applications, and can meet the full circle labeling or semi circle labeling of round bottles. The labeling switching between bottles is simple and easy to adjust. Blister packaging machine is a machine that uses transparent plastic film or sheet to form a blister and seals the product between the blister and the bottom plate by means of heat sealing and bonding. Application: capsule, plain tablet, sugar coating, capsule, injection, abnormity, etc., as well as sealed packaging of medical devices, light food, electronic components blister.

Why is Proper Humidity Important in Clean Rooms? Maintaining proper humidity levels in clean rooms is crucial for several reasons: Prevention of Condensation: High humidity levels can cause condensation on surfaces, leading to potential damage to sensitive equipment or materials. Lower humidity levels prevent this issue by reducing water vapor in the air. Mold Growth: High relative humidity levels promote the growth of mold and mildew, which can negatively impact the cleanliness and functionality of clean rooms. Ensuring proper humidity levels helps prevent mold growth and associated health hazards.

The plane and space design of the clean laboratory will arrange the clean experimental area and personnel purification, equipment and material purification and other auxiliary rooms in different areas. At the same time, the comprehensive coordination effects of various technical facilities, such as experimental operation, process equipment installation and maintenance, air distribution type, pipeline layout and purified air conditioning system, are considered.

The detection of air volume and wind speed must be carried out first, and all effects of purified air conditioning must be obtained under the designed air volume and wind speed. Before air volume detection, it is necessary to check whether the fan operates normally, whether all components in the system are installed correctly and whether there are obstacles (such as whether the filter is blocked or blocked). All valves should be fixed at a certain opening position, and the size of the measured air outlet and air duct must be measured. For the turbulent flow clean room, the air supply volume shall be determined by the air outlet method or air duct method. See Item 6, 7 and 8 respectively. For the air outlet without filter, the method in Appendix I of the current national standard code for construction and acceptance of ventilation and air conditioning engineering (gbj243) can be implemented.