Tablet punches and dies manufacturer and supplier in China: Air filter refers to the air filter device, which is generally used in clean workshop, clean workshop, laboratory and clean room, or used for dust prevention of electronic machinery communication equipment. There are primary filter, medium efficiency filter, high efficiency filter and sub high efficiency model. Different models have different standards and performance. The comprehensive performance test of clean room includes: Wind speed, air volume (ventilation frequency), temperature and relative humidity, suspended particle number, planktonic bacteria, settling bacteria, static pressure difference, illumination, noise, air flow pattern, self purification time, high-efficiency filter leak detection, total bacterial colonies in the air, total bacterial colonies on the surface of the worktable, total bacterial colonies on the surface of the worktable, total bacterial colonies on the surface of workers’ hands, etc. See additional information on tablet punches and dies.
Clean room (aseptic room) should meet the standard requirements: The aseptic room should have good lighting, avoid moisture and stay away from contaminated areas. The area is generally not more than 10㎡, not less than 5㎡and the height shall not exceed 2.4m. It is composed of 1-2 buffer rooms and operation rooms (The doors of the operation room and buffer room should not be directly opposite); Transfer window with sterilizing function between handling room and buffer room. In the buffer room, there should be a wash sink, sterile clothes, slippers and wardrobe, etc., there should not be other debris placed. The wall of the sterile room should be smooth and smooth, and can withstand cleaning and disinfection.
V-type mixer series products are high-efficiency asymmetric mixers, which are applicable to the mixing of powder particles with good material fluidity and small physical property differences, as well as the mixing of materials with low mixing degree and short mixing time. Since the flow of materials in the V-type mixing container is stable and will not damage the original shape of materials, the V-type mixer is also applicable to the mixing of granular materials that are easy to break and wear, or fine powder particles, blocks. It is widely used in pharmaceutical, chemical, food and other industries.
As industries and research labs continue to embrace clean rooms as essential components of their operations, it’s crucial for professionals to understand the ideal cleanroom humidity levels within these controlled environments. Clean rooms, also known as sterile rooms or anti-static rooms, are designed to minimize contamination from dust, debris, and other environmental factors. Maintaining optimal humidity levels is an integral part of ensuring the cleanliness and functionality of clean rooms. In this blog post, we’ll discuss the normal humidity range for clean rooms and how to maintain them effectively.
Mainly control the pollution of air dust particles and organisms (bacteria) to working objects, and maintain a negative pressure with the atmosphere inside. Pharma cleanroom project It is suitable for precision machinery industry, electronics industry, aerospace industry, high-purity chemical industry, atomic energy industry, optomagnetic product industry, LCD, computer hard disk; pharmaceutical industry, hospital, operating room, sterile ward, food, cosmetics, beverage products Animal laboratory, physical and chemical laboratory, blood station, etc. More cases check our cleanroom project page.
For the tuyere equipped with filter, the auxiliary air duct can be selected according to the tuyere form, that is, the straight pipe section with the same section as the tuyere and the length equal to twice the side length of the tuyere is made of hard plate, which is connected to the outside of the filter tuyere. The measuring points are evenly arranged on the outlet plane of the auxiliary air duct according to the minimum number of measuring points, and the wind speed of each point is measured with a hot ball anemometer. The air volume is determined by multiplying the average wind speed at the section of the air outlet by the net section area of the air outlet.
Pharma machinery manufacturer and supplier 2024: Today (Suzhou Pharma Machinery Co., Ltd.) will introduce to you, clean room airflow and influencing factors. There are many factors affecting the airflow in the clean room, such as process equipment, personnel, clean room assembly materials, lighting fixtures, etc. At the same time, the distribution point of airflow above the production equipment should also be considered.
Clean shed, also known as clean work shed (dust-free shed, purification shed, operating table, etc.), is a small space surrounded by anti-static mesh curtains or plexiglass in the clean room, and HEPA and FFU air supply units are used above. It is composed of a space with a higher purification level than the clean room, and the clean room can be equipped with purification equipment such as air shower room and transfer window.
Suzhou Pharma is one of the leading turnkey project providers for pharmaceutical, food, herbal, cosmetic, electronics factory and chemical plants. We offer projects as per GMP regulations. As being pioneers in this field, the solutions from Suzhou Pharma is readily accepted by the customers. Our solid expertise in cleanroom allows meeting the precise needs of its customer’s industry in different sectors such as health,pharmaceutical, biotechnology, and cosmetics. We firmly believe in the principle of quality by design. Read even more details at sz-pharma.com.